2 Hour Burn Rate Fire Proof Coax. Cable (50 Ohm) - Custom Lengths Available

2 Hour Burn Rate Fire Proof Coax. Cable (50 Ohm) - Custom Lengths Available
Buy Now, Pay Later with No Interest if paid in full within 6-12 months. Choose Klarna payment option at the checkout for details of this, and other long-term low-interest financing options.
Free Lifetime Support. SKU / Model: AFW-FIREPROOFCABLE-1
1(855)846-2654
Need installation quote, or help with designing a custom solution? Submit a request for quote.
- Description
- Reviews
- Questions & Answers
- Make An Offer
- Warning
Description
Product Description
2 hour burn rate fire proof coaxial cable (50 ohm). This American fire wire provides low loss plus it is a two hours fire burn rated coax. cable. It consists of proprietary materials including braided copper. It is half an inch thick. It has a red polyolefin jacket. It is the best 2-hour rated coaxial communications cable in the market. Read 2 hr. burn rate coax cable spec. sheet.
It can be purchased cut to length as chosen in drop-down menu, or call for custom lengths not shown. Connectors required but not included. Proprietary two hour burn rate fire proof cable connectors (N-Male) and connector installation kit for 2 hr. burn rate cable, if needed, must be purchased separately. Read cable connectorization instructions on how to install the connector on the cable.
Why is it the highest quality fireproof cable?
It can operate while exposed to 1850 degrees Fahrenheit for over two hours meeting the NFPA 70 and 72 requirements.
Features
- Performance: This American fire wire Meets 2 hr. fire rating survivability requirements.
- Flexibility: This American firewire eliminates electrical and mechanical issues in tight areas.
- Application: This Americanfire wire provides in-building public safety DAS where 2-hour survivability is required.
- Cost Savings: Eliminate costly wraps and save up to 200% per feet over archaic methods.
Construction Materials:
Jacket Material: | Polyolefin. |
---|---|
Outer Conductor Material: | Tinned Copper Braid. |
Di-Electric Material: | Foam Polyolefin / Foamed CF Silicon. |
Flexibility: | Standard. |
Inner Conductor Material: | Bare Copper Wire. |
Jacket Color: | Red. |
Dimensions:
Nominal Size: | 7/8 inch. |
---|---|
Cable Weight: | 0.66 kg/m. |
Diameter Over Dielectric: | 16.383 mm | 0.645 in. |
Diameter Over Jacket: | 22.860 mm | 0.900 in. |
Inner Conductor OD: | 15.240 mm | 0.645 in. |
Electrical Specifications:
Cable Impedance: | 50 Ohm (+/- 2 Ohm). |
---|---|
Capacitance: | 75.8 pF/m | 23.1 pF/ft. |
DC Resistance, Inner Conductor: | 1.480 ohms/km. |
DC Resistance, Outer Conductor: | 2.690 ohms/km. |
DC Test Voltage: | 600 V. |
Inductance: | 0.190 μH/m | 0.058 μH/ft. |
Insulation Resistance: | 100,000 Mohms/km. |
Jacket Spark Test Voltage (rms): | 600V RMS. |
Operating Frequency Band: | 1 to 8800 MHz. |
Peak Power: | 40.0 kW. |
Velocity: | 78%. |
Attenuation:
150 MHz: | 2.65 dB / 100 ft. |
---|---|
450 MHz: | 3.44 dB / 100 ft. |
700 MHz: | 7.64 dB / 100 ft. |
800 MHz: | 7.89 dB / 100 ft. |
Mechanical Specifications:
Bending Moment: | 3.8 N-m | 2.8 ft. lb. |
---|---|
Flat Plate Crush Strength: | 2.0 kg/mm. |
Minimum Bend Radius, Multiple Bends: | 127.00 mm | 5.00 in. |
Minimum Bend Radius, Single Bend: | 50.80 mm | 2.00 in. |
Number of Bends, minimum: | 15. |
Number of Bends, typical: | 50. |
Tensile Strength: | 113 kg | 249 lb. |
Environmental Specifications:
Installation Temperature: | -40 Degrees C to +60 Degrees C (-40 Deg. F to +140 Deg. F). |
---|---|
Operating Temperature: | -55 Degrees C to +85 Degrees C (-67 Deg. F to +185 Deg. F). |
Storage Temperature: | -70 Degrees C to +85 Degrees C (-94 Deg F to + 185 Deg. F). |
Standard Conditions:
Attenuation, Ambient Temperature: | 20 Degrees Centigrade | 68 Degrees Fahrenheit. |
---|---|
Average Power, Ambient Temperature: | 40 Degrees Centigrade | 104 Degrees Fahrenheit. |
Average Power, Inner Conductor Temperature: | 100 Degrees Centigrade | 212 Degrees Fahrenheit. |
Regulatory Compliance / Certifications:
Agency: | Western Fire Center Evaluation Report # 19089, Evaluation Report Date 10/29/2019. |
---|---|
Classification: | Standards Evaluated to: ASTM E119, Standard Test Methods for Fire Tests of Building Construction and Materials (this test method is also published under the designation of UL 263). |
ASTM: | E119. |
---|---|
RoHS 2011/65/EU: | Compliant. |
ISO 9001:2015: | Designed, manufactured and/or distributed under this quality management system. |
RoHS S/JT 11364-2014: | Above Maximum Concentration Value (MCV). |
Stamp approval code: | 73-AFW-2HFR-3 / 73AFW2HFR3. |
CENELEC: | EN 50575 compliant, Declaration of Performance (DoP) available. |